Color: | White And Grey | Mode: | S/T, CPAP, S, T, PC, VAT, HFNC |
---|---|---|---|
Screen Size: | 5.7 Inch Color Screen | Oxygen Concentration: | 21%~100%, (increment By 1%) |
Target Tidal Volume: | 20~2500mL | Backup BPM: | 1~60BPM |
Flow Of HFNC Mode: | 10~70L/min | Max Flow: | 300L/min |
Max Leak Compensation: | 120L/min | IPAP: | 4~40cm H2O |
EPAP: | 4~25cm H2O | CPAP: | 4~20cm H2O |
High Light: | HFNC mode Non Invasive Ventilator Machine,300L/min Non Invasive Ventilator Machine,300L/min non invasive ventilation device |
HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HFNC MODE
Description
Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy and delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.
Non-invasive ventilation (NIV) is ventilator support given to patients without the use of an endotracheal tube.
Application
The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.
Non-invasive mechanical ventilation has been increasingly used to avoid or serve as an alternative to intubation. Compared with medical therapy, and in some instances with invasive mechanical ventilation, it improves survival and reduces complications in selected patients with acute respiratory failure.
Advantage
AST-Premium technology will monitor patients’ every single respiration, response immediately to synchronize patients’ breath through sensitivity trigger by detecting flow, pressure and waveform changing.
Automatic-Sensitivity technology provide the doctor convenience no need to set the sensitivity manually, and lower down patient’s respiratory power.
- Trigger sensitivity: support automatic trigger and 3 levels trigger sensitivity adjustment. The lower the trigger sensitivity is, the less work the patient needs to do to trigger, and the easier the ventilator is to trigger.
- Withdraw sensitivity: support automatic withdraw and 3-level withdraw sensitivity adjustment. The lower the sensitivity, the less work patients need to do to remove the ventilator, and the easier it is to remove the ventilator.
5.7-inch LCD color screen, flow rate and pressure double waveform, setting, alarm, treatment information displayed on the screen, combined with a knob. A single page can complete all settings.
Specifications
|