Color: | White And Grey | Mode: | S/T, CPAP, S, T, PC, VAT |
---|---|---|---|
Screen Size: | 5.7 Inch Color Screen | Oxygen Concentration: | 21%~100%, (increment By 1%) |
Target Tidal Volume: | 20~2500mL | Backup BPM: | 1~60BPM |
Max Flow: | 210L/min | Max Leak Compensation: | 90L/min |
IPAP: | 4~30cm H2O | EPAP: | 4~25cm H2O |
CPAP: | 4~20cm H2O | ||
High Light: | noninvasive hospital ventilator machine,Noninvasive micomme ventilator,25cm H2O Micomme Ventilator |
HOSPITAL VENTILATOR ST-30H with NON-INVASIVE VENTILATION SOLUTION
Description
Non-invasive ventilation (NIV) is the delivery of oxygen (ventilation support) via a face mask and therefore eliminating the need of an endotracheal airway. NIV achieves comparative physiological benefits to conventional mechanical ventilation by reducing the work of breathing and improving gas exchange.
Non-invasive ventilation (NIV) is ventilator support given to patients without the use of an endotracheal tube. It results in the potential complications of invasive mechanical ventilation being avoided. It also helps to deliver cost-effective therapy with decreased length of stay in the ICU and an improved chance of survival.
Application
Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
Increased quality of life: NIV increases the quality of life for patients.
Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.
Advantage
Automatic-Sensitivity technology provide the doctor convenience no need to set the sensitivity manually, and lower down patient’s respiratory power.
- Trigger sensitivity: support automatic trigger and 3 levels trigger sensitivity adjustment. The lower the trigger sensitivity is, the less work the patient needs to do to trigger, and the easier the ventilator is to trigger.
- Withdraw sensitivity: support automatic withdraw and 3-level withdraw sensitivity adjustment. The lower the sensitivity, the less work patients need to do to remove the ventilator, and the easier it is to remove the ventilator.
Leakage compensation performance, the device offers 90L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.
Specifications
|