Oxygen Ajustment: | Automatic | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-70L/min | Temperature: | 31-37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | 70L / Min High Flow Nasal Oxygen Therapy Unit,70L / Min High Flow Oxygen Equipment,70L / Min high flow oxygen delivery system |
Micomme OH-Series high flow nasal cannula HFNC oxygen therapy device 70C
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.
A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.
Application
Its use has been widely explored, particularly in ICUs and emergency departments (EDs)
The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.
Advantage
The first company to research, develop and produce high-flow in China.
At present, micomme occupies over 50% market share in high flow filed in China.
Automatic O2 concentration control technology
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Effectively reduce the dead space with 70L/min high flow
Specifications
Parameters | OH-70C |
Oxygen Adjustment Setting | Automatic |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 70L/min |
Temperature settings | 31℃- 37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |