Oxygen Adjustment: | Manual | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 60L/min |
Temperature Settings: | 31℃,34℃,37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | High Performance High Flow Oxygen Therapy Machine,7days Review High Flow Oxygen Therapy Machine,High Performance high flow oxygen therapy equipment |
Micomme OH-60A home-use high flow nasal cannula HFNC device, with high performance
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.
Application
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
Other applications of HFNC include the prevention of postextubation hypoxaemia, pre-oxygenation before sedation/anaesthesia and oxygenation during bronchoscopy.
Advantage
At present, micomme occupies over 50% market share in high flow filed in China.
In 2020, micomme ranked the sixth in export of medical respiratory devices in China.
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Intelligent water-controlling system, automatically maintaining the optimal water level in the water chamber.
Specifications
Model | OH-60A | ||
Oxygen Adjustment | Setting | Manual | |
Range | 21%-100% | ||
Flow |
Low flow mode | 2-25L/min | |
High flow mode | 10-60L/min | ||
Temperature settings | 31℃, 34℃, 37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
Data |
Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
Management |
Auto reminder of maintenance | Yes | |
Main device disinfection |
No need disinfection for circuits system Wipe disinfection for device surface |
||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
Alarm |
Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |